In the second wiring diagram, the lamp is connected directly to the line terminals of GFCI (i.e. direct main power supply). Next, the wiring may extend out to the light switch where only the black power wire is connected through the switch and the white neutral wires are spliced together. Wiring a GFCI Outlet with a Light Switch and Protected Receptacle In this wiring, the gfci protects a standard duplex receptacle connected to the LOAD terminals on the combo. The built-in switch controls an unprotected light fixture on a separate electrical source.
The source to the outlet is connected to the LINE terminals on the gfci. Most electricians are probably not going to tell you how to do this because there is a liability involved and because electricity is dangerous and any mistakes can cause injury or death by electrocution or by fire. Free Shipping Available On Many Items. Find China Manufacturers Of Gfci. Money Back Guarantee!
But Did You Check eBay? Check Out Receptacle Gfci And Switch On eBay. It means, all the connected loads to the load terminals of GFCI are protected. Free 2-day Shipping On Millions of Items. Looking For Light Switch ? We Have Almost Everything On eBay.
Improve Your Business ROI - Get A Better Deal On Gfci. If the switch box is the location where all of these wires are found individually then the separation may be possible. With the switch off, the outlet is denergized and only has a neutral and ground connected to it. This diagram illustrates wiring a GFCI receptacle and light switch in the same outlet box, a common arrangement in a bathroom with limited space.
The hot source is spliced to the LINE terminal on the receptacle and to one terminal on the light switch. Turning the light switch on will energize the outlet. The neutral and ground wires are spliced together and run to each device in the circuit. You can physically wire it from the GFCI box, or from either of the outlet boxes, whichever is closest to your switch box.
AWG for 20A breakers, or 14AWG for 15A, and staple the romex wires to the stud close to the box they run into. There may be other code requirements in your area that a local electrician can help you with. They have two pairs of terminals.
If the device fails the test, it will trip, and the red light will turn on. You can connect several more outlets on the LOAD terminals, and they will also be protected from ground faults. You can also add a switch , though bear in mind that highly inductive loads (like a large motor) can cause nuisance tripping of the GFCI.
The yellow light indicates one of three problems. Reset the receptacle. If the light will not go out, replace the receptacle. GFCI outlets have LINE and LOAD terminals.