Wednesday, 21 March 2018

Astm c840

Astm c840

Control joints shall be installed where indicated on the plans. The work identifies five specific lev- els of finishing, enabling architects to more closely identify the sophis- tication required and allowing for better competitive bidding among contractors. View all product details.


Astm c840

The above-mentioned trade associations periodically publish revised versions of the Levels of Gypsum Board Finish. Foil-Backed Gypsum Panel Products. Recommended Levels of Gypsum Board Finish. ASTM International 1. In some cases when control joints are specifie the drawings are not coordinated with the specifications and the control joint details are frequently missed.


A number in parentheses indicates the year of last reapproval. Application and finishing of Gypsum Board. as PDF File (.pdf), Text File (.txt) or read online for free. Construction details for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or from recognized fire testing laboratories.


SPECIFICATION FOR STEEL DRILL SCREWS FOR THE APPLICATION OF GYPSUM PANEL PRODUCTS OR METAL PLASTER BASES TO STEEL STUDS FROM 0. This document has been replaced. MOLD AND MILDEW RESISTANCE Hi-Impact XP Gypsum Board was designed to provide extra protection against mold and mildew compared to standard gypsum board products. Synthetic bonding agents are the responsibility of each individual manufacturer of EIFS and is not the responsibility of the suspension system manufacturer.


Gypsum wallboar designed for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration. When walls are more. Install two studs at each jamb unless a framing member has been specifically engineered for the jamb. Extend jamb studs through suspended ceilings and attach to underside of overhead structure if suspended ceiling system cannot withstand forces imposed by door swings. ASG Multi Purpose Joint Compound used for taping, finishing Gypsum Board Joints, filling, covering and for Final Touch-Up Coats in Interior Gypsum Board applications.


Astm c840

It is an ideal material for embedding fasteners, corner surfaces where necessary. It can also be used to repair the crack on the brick wall surface. For fire resistance treated construction, application regarding board orientation, fastener type and spacing shall be consistent with the tested construction details. Standard Specification for App $72.


For fire-resistance-rated applications, refer to the published UL Design or GA File Number. Remedy all defects prior to installation of the gypsum board. For fire resistance rated construction application regarding board orientation, fastener type and spacing shall be consistent with the tested construction details for Type X Gypsum Board.


Astm c840

Gypsum board shall be cut by scoring and breaking or by sawing, working from the face side. The design professional has the ultimate responsibility for location of control joints. Leaded glass leaded Glass shall meet or exceed Federal Specification DD-G-451.


These details are based on Warnock Hersey International, Inc. Indexed Support Bar (ISB109) end terminations must be attached to wall angle and must be overlapped. Some manufacturers of light gauge steel framing provide products of lesser steel thickness. LOL needless to say, I had to search the internet to get a simple description of what they meant. Do not install interior products until installation areas are enclosed and conditioned.


QQ-1-101C ANSI A42. Fire Resistant Assemblies See the Gypsum Association. American Society for Testing and Materials, West Conshohocken, PA DWFC.


Lath shall not be continuous through control joints, but shall be stopped and tied at each side” In summary – Structa Wire Corp.

No comments:

Post a Comment

Note: only a member of this blog may post a comment.